KENCO ENGINEERING COMPANY
P.O. BOX 470426 TULSA, OK 74147-0426
PHONE(918) 663-4406 FAX: (918) 663-4480
www.kenco-eng.com e-mail:[email protected]
INSTALLATION INSTRUCTIONS FOR MODEL KLCM OIL LEVEL CONTROLLERS WITH ADAPTERS
(INCLUDING HIGH PRESSURE MODELS)
Note: For fire safe oil level controllers (LCM-FS) see additional instructions in this work sheet covering installation of fire safe
valves.
I. SWITCH SPECIFICATIONS:
Figure 1: Model LCM Switch Wire Color Code
Note: Switch trip point is factory set at a ¾” drop . For adjustment instructions, please consult the factory.
II. INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR OIL INLET VALVE:
Connect the oil supply line to the oil inlet on the oil level controller. The minimum recommended supply line is ¾” I.D. The
supply line must be clean and it is recommended that it be flushed with solvent before installation.
Connect the oil supply line to the oil supply tank. If there is no existing valve at the tank or the existing supply outlet, a shut-off
valve should be placed in the line to prevent oil loss when cleaning the inlet screen or filter.
For high pressure models HP-A, pressure range must be between 5 psi and 34 psi. For high pressure units HP-
B , pressure
range must be between 35 psi and 70 psi.
The oil inlet valve is adjusted to maintain the oil level at the center of the sight glass. Low or high levels are often caused by
two problems:
1. Excessive oil inlet pressure, which will cause the unit to overfill.
2. Improper equalizing lines between the crankcase and the controller will also result in improper levels.
Note: Low pressure models require a minimum of 2’ of head pressure and a maximum of 15’ of oil inlet head pressure.
III. INSTALLATION INSTRUCTIONS FOR UNITS WITH ADAPTERS:
OIL LEVEL CONTROLLERS WITH
–1
(Clark MA & CFA)
–2
(Clark HMB & TMB),
-3
(Clark RA, HRA, HBA, HCA, HLA,
TLA),
-6
(Cooper-Bessemer GMW),
-7
(Cooper-Bessemer GMV),
-8
(Cooper-Bessemer GMX),
-16, -16-R, -16-6.25
(Cooper-
Bessemer BMV & 275) AND FS OPTIONS
Remove the visual oil gauge assembly from the engine and replace it with the oil level controller and adapter assembly supplied
with a gasket and mounting bolts when applicable.
OIL LEVEL CONTROLLERS WITH
–4
(Ingersoll-Rand SVG & KVS),
-5
(Ingersoll-Rand KVG) AND FS OPTIONS
Remove the visual oil gauge assembly from the engine and replace it with the oil level controller and adapter assembly supplied
with a gasket and mounting bolts when applicable.
If an equalizing exists for the engine sight glass and detach the equalizing line from the sight glass while still attached to the
engine.
Install the oil controller and then reattach the equalizing line to the vent located at the top of the adapter.
Note: It is important to insure that there are no loops in this line for it must be trap free and self draining.
Electrical Ratings:
10 AMP, 125/250 VAC
0.5 AMP, 125 VDC
0.25 AMP, 250 VDC
1/8 HP, 125 VDC
¼ HP, 250 VAC
125 VAC “L”Lamp Load
Circuitry: Single Pole Double Throw
Class III,
Type 4
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - KENCO ENGINEERING COMPANY

KENCO ENGINEERING COMPANYP.O. BOX 470426 TULSA, OK 74147-0426PHONE(918) 663-4406 FAX: (918) 663-4480www.kenco-eng.com e-mail:[email protected]

Página 2 - Figure 3

OIL LEVEL CONTROLLERS WITH –9 (Universal adapter), -10(Slotted universal adapter),-12 (Pole mounted adapter) AND –FS OPTIONS• Set the controller so t

Página 3

OIL LEVEL CONTROLLER WITH –17 (Waukesha VHP Engines F2895, F3251, F5108, L5790 & L7042), -18 (-17 w/ meter), -27(for newer Waukesha engines same a

Página 4 - V. START-UP PROCEDURES

IV. INSTALLATION INSTRUCTIONS FOR FIRE SAFE VALVES: See Figure 5 belowMODEL 50-FS AND 75-FS (PATENT NO. 3,877,476)NOTE: All lines between thermal val